Everything public in src/MQGasSensor.h. The site build fails if this page and the header disagree about which methods exist.

Units throughout: volts, kilohms, and the concentration unit of the curve, which is ppm for most curves and mg/L for the MQ-3's.

Types

MQModel is the shape of a curve:

Value Concentration
MQModel::PowerLaw a × ratio^b, the form every fitted coefficient uses
MQModel::LogLinear 10^((log10(ratio) − b) / a), a straight line on log-log axes written with its slope a and intercept b

MQRatio is the ratio a curve is plotted against:

Value Ratio
MQRatio::RsOverR0 Rs/R0, the default, which most datasheets plot
MQRatio::R0OverRs R0/Rs, which the MQ-131 datasheet plots

Construction and setup

MQGasSensor(pin, adcRefVolts = 5.0, adcBits = 10, name = "MQ")

pin is the analog input the sensor's output is wired to. adcRefVolts and adcBits describe the ADC that reads it, and turn a raw reading into volts. The sensor's supply voltage starts equal to adcRefVolts. name is only shown by printDebug; up to 11 characters are kept.

begin()

Sets the pin as an input. Skip it when an external ADC reads the sensor and the pin is used for something else.

setLoadResistance(kOhm)

RL, the resistor the sensor drives on its module. Default 10 kΩ.

setSupplyVoltage(volts)

The voltage across the sensor and RL, used in Rs. Default: the ADC reference.

setAdcReference(volts)

The ADC's reference voltage, used to turn a raw reading into volts.

setSupplyOffset(volts)

Subtracted from the supply voltage wherever Rs is computed, including in calibrate. The MQ-303A examples set 0.45. Default 0.

setCurve(a, b, model = MQModel::PowerLaw)

The curve readPpm and ppmFromRatio use. Every call sets the model too, so a sketch that switches between curves passes it each time. a is limited to ±10^30 and b to ±100; a value that is not a finite number becomes 0.

setRatio(ratio)

Which ratio readPpm computes: MQRatio::RsOverR0 (the default) or MQRatio::R0OverRs. calibrate always takes the clean-air ratio as Rs/R0, whichever is set.

setCorrection(factor)

readPpm divides the ratio by factor before the curve, for an environmental correction such as temperature and humidity. Default 1.0, no correction.

Calibration

calibrate(cleanAirRatio, r0Offset = 0.0)

Sets R0 to Rs from the last update divided by cleanAirRatio, the datasheet's Rs/R0 in clean air, plus r0Offset, and returns it. A negative result becomes 0. If the last update read 0 V, R0 is infinite; if it read the supply voltage or more, Rs and so R0 are 0.

setR0(kOhm = 10)

Sets R0 directly, for a value calibrated earlier and stored.

Reading

update()

Reads the pin twice, 20 ms apart, and keeps the average as the sensor voltage. It takes about 40 ms. Returns false if that is 0 V, which means the sensor is disconnected or unpowered.

updateFromVoltage(volts)

Uses a voltage measured elsewhere, such as by an external ADC, as the sensor voltage. Returns false if it is 0 or less.

updateFromRaw(raw)

Uses a raw ADC value measured elsewhere, converted with the reference and resolution given to the constructor. Returns false if it is 0.

readPpm()

Computes Rs from the last update, the ratio (setRatio) divided by the correction (setCorrection), and the concentration from the curve, and returns the concentration. Returns NAN if the last update read 0 V. A concentration too large for a float is returned as FLT_MAX.

ppmFromRatio(ratio)

The concentration the curve gives for ratio, without reading anything. 0 for a ratio of 0 or less, or before a curve is set.

Inspection

rs()

Rs in kΩ for the last update's voltage. Infinite at 0 V; 0 when the voltage reaches the supply.

ratio()

The ratio the last readPpm used, after the correction. NAN if that read found 0 V.

voltage()

The sensor voltage from the last update.

r0()

R0 in kΩ.

a()

The curve's a, after limiting.

b()

The curve's b, after limiting.

printDebug(out = Serial)

Prints one line to out, any Print such as Serial or an LCD library's object:

MQ-2: V=1.00 V, Rs=40.00 kOhm, R0=4.21 kOhm, ratio=9.51, ppm=4.44 (a*ratio^b, a=564.77, b=-2.15)

That line is from a simulated Mega 2560: an MQ-2 on its LPG curve, calibrated with calibrate(9.51) at 1.00 V and read at the same voltage.

Rs is computed from the current voltage; the ratio and ppm are those of the last readPpm.