iso4796-bottle-scad
ISO 4796-1 screw-neck laboratory bottles (the DURAN / KIMAX-style media bottle) in OpenSCAD: the standard’s size table, a section built from it, what each bottle holds, and a drawing with the DIN 168 thread optional.

use <iso4796-bottle-scad/iso4796.scad>
b = iso4796_by_capacity(500);
iso4796_bottle(b); // the bottle, base on z = 0, thread band as a plain cylinder
iso4796_bottle(b, thread=true); // with the GL45 thread (needs din168-thread-scad)
iso4796_bottle(b, angle=270); // cut away
iso4796_volume_below(b, 100); // mL held when filled to 100 mm
iso4796_report(b); // echo the capacity against what the standard asks
- Sizes: every size in ISO 4796-1:2016, 25 mL to 20 L (
iso4796_sizes, in the standard’s order). The table, the capacities and the 1:30 taper from 3.5 L are the standard’s; every figure is recorded with its source in docs/references.md. - Neck: the standard leaves the thread to DIN 168 and does not name one. The finish per size is what DURAN puts on it: GL25 at 25 mL, GL32 at 50 mL, GL45 from 100 mL. The bores (14.3, 17, 30 mm) are published figures, not the standard’s minima.
- Thread: off by default, so the library needs nothing else. The thread band is then drawn at
the thread’s outside diameter, which is its envelope.
thread=truedraws the DIN 168 profile from din168-thread-scad, which must then be onOPENSCADPATH. Without it OpenSCAD prints oneCan't open librarywarning, and athread=truecall stops with an assertion naming the library. With scadman,scadman.tomlpins din168-thread-scad at v0.1.0:scadman sync, thenscadman envprints theOPENSCADPATHto use. - What is chosen, not sourced: the base and shoulder radii, the base thickness, and the neck’s
lengths. Each is a named variable marked CHOICE in
iso4796.scad. The cone is not chosen: it is whatever fits between the shoulder and the neck. - Capacity:
iso4796_report()compares what the drawn bottle holds with the standard’s capacities. From 3.5 L up it is within 5 %; from 25 mL to 2 L it holds 11-45 % too much, for reasons in docs/references.md. Treat small bottles’ capacities as unverified until a measured bottle corrects the choices.
Sizes
iso4796_by_capacity(ml) returns a size. Heights and diameters in mm, approximate as the standard
gives them.
| mL | h1 | h2 | d1 | s min | d2 min | Finish |
|---|---|---|---|---|---|---|
| 25 | 70 | 41 | 36 | 1.0 | 12.5 | GL25 |
| 50 | 87 | 50 | 46 | 1.0 | 15 | GL32 |
| 100 | 100 | 60 | 56 | 1.5 | 27 | GL45 |
| 150 | 110 | 70 | 62 | 1.5 | 27 | GL45 |
| 250 | 138 | 90 | 70 | 1.5 | 27 | GL45 |
| 500 | 176 | 110 | 86 | 1.5 | 27 | GL45 |
| 750 | 204 | 133 | 95 | 1.7 | 27 | GL45 |
| 1 000 | 225 | 153 | 101 | 1.7 | 27 | GL45 |
| 2 000 | 260 | 170 | 136 | 2.0 | 27 | GL45 |
| 3 500 | 295 | 184 | 161 | 2.0 | 27 | GL45 |
| 5 000 | 330 | 208 | 181 | 2.0 | 27 | GL45 |
| 10 000 | 410 | 265 | 227 | 2.7 | 27 | GL45 |
| 15 000 | 445 | 285 | 268 | 2.7 | 27 | GL45 |
| 20 000 | 505 | 330 | 288 | 3.0 | 27 | GL45 |
Examples
- examples/all_sizes.scad: every size in a row, labelled, with each capacity report echoed.
- examples/500ml_section.scad: a 500 mL bottle cut away. Its
threadswitch, off by default, draws the GL45 thread.
Maker-specific bottles
A size is a row, [name, capacity, h1, h2, d1, s, d2, finish]. A maker’s bottle is the same row
with its maker’s numbers, in a file per maker, and every function here reads it:
use <iso4796-bottle-scad/iso4796.scad>
use <iso4796-bottle-scad/duran.scad>
use <iso4796-bottle-scad/kimax.scad>
iso4796_bottle(duran_by_capacity(3500)); // DURAN 21 801 69 08: 160 across, where ISO says 161
iso4796_report(duran_by_capacity(1000)); // also sets the drawn bottle against DWK's brim capacity
iso4796_bottle(kimax_by_capacity(500)); // KIMAX 14396-500
- duran.scad: DURAN Original, 25 mL to 20 L, named by catalogue number. Height and diameter from DWK’s order sheet, which differs from the standard in three places (750 mL, 3.5 L, 5 L); brim capacity where DWK publishes one, carried as a ninth field.
- kimax.scad: KIMBLE KIMAX GL45 media bottles, 100 mL to 10 L, catalogue 14396. Height and diameter as DWK lists them, all equal to the standard’s.
Neither maker publishes the height to the shoulder, the wall or the neck, so their rows take the standard’s. Rows for other makers, and for generic Boro 3.3 bottles, are tracked in the issues.
Checks
just test syncs din168-thread-scad with scadman and takes about 3 s on OpenSCAD 2026.10.15, with
warnings treated as errors:
- The ISO rows match Table 1, the DURAN rows DWK’s sheet and brim capacities, and the KIMAX rows Table 1’s d1 and h1, all as docs/references.md records them.
- What each drawn bottle holds, to the shoulder, to the neck and, for DURAN, to the rim, rounds to the percentages its Findings record.
- Every size renders as one solid, d1 across and h1 tall; so do the 25, 50 and 500 mL bottles with their GL25, GL32 and GL45 threads drawn, and both examples.
- The three lookups refuse a capacity they don’t have, each with its message.
just images renders the picture above.